Show simple item record

dc.contributor.authorO'LUANAIGH, NIALL
dc.contributor.authorJOHNSTON, PAUL
dc.contributor.authorMISSTEAR, BRUCE
dc.contributor.authorPATEL, TITIKSH
dc.contributor.authorGILL, LAURENCE
dc.contributor.editorN.D., O'Luanaighen
dc.contributor.editorP.J., Johnstonen
dc.contributor.editorB., Misstearen
dc.contributor.editorT., Patelen
dc.contributor.editorL.W., Gillen
dc.date.accessioned2009-11-25T15:39:19Z
dc.date.available2009-11-25T15:39:19Z
dc.date.issued2009
dc.date.submitted2009en
dc.identifier.citationNiall O?Luanaigha, Paul Johnstona, Bruce Missteara, Titiksh Patelb, Laurence Gilla `A comparative study on the treatment performance of a conventional septic tank system and reed bed-soil absorption system receiving domestic effluent? in Desalination and Water Treatment, 4, 2009, pp 45-53en
dc.identifier.otherY
dc.identifier.otherYen
dc.identifier.urihttp://hdl.handle.net/2262/34967
dc.descriptionPUBLISHEDen
dc.description.abstractIn Ireland, the most prevalent domestic wastewater treatment application in unsewered areas is the conventional septic tank system comprising of septic tank and soil absorption system, the latter more commonly referred to as a percolation area in Ireland. Recent concern has been expressed over the discharge of on-site effluent to highly permeable soils which, although permitted in current Irish EPA guidelines, has generated debate as to whether an insufficient level of treatment in the subsoil?s vadose zone is being achieved. In situations where a septic tank installation is considered unsuitable according to a rigorous site assessment, a secondary treatment system such as a horizontal subsurface-flow reed bed can be installed to improve the effluent quality before discharge to the subsoil. On-site research was thus carried out to assess and compare the treatment capabilities of freely-draining subsoils receiving both septic tank and secondary effluents in tandem with a treatment assessment of a horizontal subsurface-flow reed bed. Results over an 18-month period have shown the HF reed bed to perform poorly with removal of only 52% of the organic load. An impressive 1.9 log-unit removal in E. coli was nevertheless achieved. The majority of nitrification is seen to occur in the first 0.35m of subsoil for all sets of percolation trenches and, while coupled with poor denitrification throughout the subsoil, has compromised groundwater quality in the form of nitrate infiltration. The research also shows that in general the septic tank effluent has received a comparable quality to the secondary effluent in terms of N-loading and E. coli occurrence by the time the point of potential discharge to groundwater is reached in the subsoil.en
dc.format.extent45en
dc.format.extent53en
dc.format.extent377968 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherDesalination Publications International Science Servicesen
dc.relation.ispartofseriesDesalination and Water Treatmenten
dc.relation.ispartofseries4en
dc.rightsYen
dc.subjecton-site wastewater treatmenten
dc.subjecthorizontal flow reed beden
dc.subjectpercolation areaen
dc.subjectseptic tank effluenten
dc.titleA comparative study on the treatment performance of a conventional septic tank system and reed bed-soil absorption system receiving domestic effluenten
dc.typeJournalen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/oluanan
dc.identifier.rssinternalid62420


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record