Show simple item record

dc.contributor.authorPAVIA, SARA
dc.contributor.editorC.A., Brebbia and A. Torpianoen
dc.date.accessioned2008-03-30T09:05:28Z
dc.date.available2008-03-30T09:05:28Z
dc.date.issued2005
dc.date.submitted2005en
dc.identifier.citationS. Pavia, B. Fitzgerald and R. Howard, Evaluation of properties of magnesian lime mortar, Structural Studies, Repair and Maintenance of Heritage Architecture IX, Malta, June 2005. Vol 83 WIT Transactions on The Built Environment., edited by C.A. Brebbia and A. Torpiano , WIT Press, 2005, pp375 - 384en
dc.identifier.otherY
dc.identifier.otherYen
dc.identifier.urihttp://hdl.handle.net/2262/15378
dc.descriptionPUBLISHEDen
dc.description.abstractDue to their nature and function, historic lime mortars weather and often need to be replaced. Petrographic analysis of original mortars from Ardamullivan Castle evidenced that they were fabricated with a dolomitic limestone. Within, Ardamullivan Castle?s conservation programme it was considered to replicate the original mortars to undertake conservation works to the Castle. However, documentary research revealed that there is a lack of agreement on the properties of magnesian lime as well as a lack of experimental work in the subject. Therefore, it was deemed necessary to evaluate the properties of magnesian lime prior to its use. To this aim, dolomite was calcinated in a limekiln and the lime obtained slaked for a year. Magnesian lime mortars were then fabricated and tested in the laboratory. Porosity, densities, compressive strength, capillary suction and absorption were evaluated. The lower values of capillary raise, porosity and absorption obtained for the magnesian lime mortars when compared to those of feebly hydraulic limes suggest that magnesian lime binders would perform superiorly in areas subject to the presence of moisture. In compression, the feebly-hydraulic mix is four times stronger than the mg-lime mortar. The mg-lime mortar outperforms the feebly-hydraulic lime mix in all tests except for compressive strength. However, the compressive strength of the mg-lime mix is enough to withstand the stresses and strains typically induced when confined within conventional masonry. The results of this investigation suggest that, provided the lime has been adequately calcinated and slaked, mg-lime mortar can perform well as a building material.en
dc.format.extent375en
dc.format.extent384en
dc.format.extent178408 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherWIT Pressen
dc.relation.ispartofseriesWIT Transactions on The Built Environmenten
dc.relation.ispartofseries83en
dc.rightsYen
dc.subjectMagnesian limeen
dc.subjectlime mortaren
dc.subjecthydraulicityen
dc.subjectNHL2en
dc.subjectcapillary suctionen
dc.subjectwater absorptionen
dc.subjectporosityen
dc.subjectdensitiesen
dc.subjectpermeabilityen
dc.subjectcompresive strengthen
dc.titleEvaluation of properties of magnesian lime mortaren
dc.title.alternativeStructural Studies, Repair and Maintenance of Heritage Architecture IX.en
dc.typeConference Paperen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/pavias
dc.identifier.rssinternalid36080


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record