Show simple item record

dc.contributor.authorHEGNER, MARTINen
dc.date.accessioned2014-02-24T12:39:02Z
dc.date.available2014-02-24T12:39:02Z
dc.date.issued2012en
dc.date.submitted2012en
dc.identifier.citationJensen, J., Farina, M., Zuccheri, G., Grange, W. and Hegner, M., Quantitative, Label-Free Detection of the Aggregation of alpha-Synuclein Using Microcantilever Arrays Operated in a Liquid Environment, Journal of Sensors, 2012, 2012, Article number 874086en
dc.identifier.otherYen
dc.identifier.urihttp://hdl.handle.net/2262/68137
dc.descriptionPUBLISHEDen
dc.descriptionProtein aggregation as a cause for neurodegenerative diseasesen
dc.description.abstractEarly detection of protein aggregation is of great importance in the field of neurodegenerative diseases. The successful detection of the aggregation of the protein ?-synuclein in a quantitative, label-free manner by functionalising a microcantilever with ?-synuclein monomers and operating it in dynamic mode in the presence of ?-synuclein monomers in solution is reported. A total mass of 6?ng of ?-synuclein was detected over 9 hours on the surface of the cantilever. The result is compared to conventional fluorescence measurements of ?-synuclein aggregation under similar conditions. It is found that the label-free cantilever detection method requires a concentration of protein 50 times smaller than that of the current method and indicated potential for significantly faster response times.en
dc.description.sponsorshipThe authors would like to thank the School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin, for the use of the FLUOstar Optima microplate multidetection reader. This work was supported by Science Foundation Ireland under the CSET scheme SFI08/CE/I1432 and PI scheme SFI/09IN/1B2623.en
dc.format.extentArticle number 874086en
dc.language.isoenen
dc.relation.ispartofseriesJournal of Sensorsen
dc.relation.ispartofseries2012en
dc.rightsYen
dc.subjectprotein aggregationen
dc.titleQuantitative, Label-Free Detection of the Aggregation of alpha-Synuclein Using Microcantilever Arrays Operated in a Liquid Environmenten
dc.typeJournal Articleen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/hegnermen
dc.identifier.rssinternalid89804en
dc.identifier.doihttp://dx.doi.org/10.1155/2012/874086en
dc.rights.ecaccessrightsOpenAccess
dc.subject.TCDThemeAgeingen
dc.subject.TCDThemeNanoscience & Materialsen
dc.contributor.sponsorScience Foundation Ireland (SFI)en
dc.contributor.sponsorGrantNumberSFI08/CE/I1432en
dc.contributor.sponsorScience Foundation Ireland (SFI)en
dc.contributor.sponsorGrantNumberSFI/09IN/1B2623en


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record