High-sensitivity two-photon absorption microcavity autocorrelator

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Access

Embargo end date

Citation

T. Krug, M. Lynch, A. L. Bradley, J. F. Donegan, L. P. Barry, H. Folliot, J. S. Roberts and G. Hill, High-sensitivity two-photon absorption microcavity autocorrelator, IEEE Photonics Technology Letters, 16, 2004, 1543 - 1545

Abstract

A GaAs-AlAs microcavity device has been used as a photodetector in an autocorrelator for measuring the temporal pulsewidth of 1.5-/spl mu/m optical pulses. Enhancement of the two-photon absorption photocurrent due to the microcavity structure results in an autocorrelation (average power times peak power) sensitivity of 9.3/spl times/10/sup -4/ (mW)/sup 2/, which represents two orders of magnitude improvement when compared with conventional autocorrelators

Description

PUBLISHED

Endorsement

Review

Supplemented By

Referenced By

Author's Homepage: http://people.tcd.ie/bradlel