The University of Dublin | Trinity College -- Ollscoil Átha Cliath | Coláiste na Tríonóide
Trinity's Access to Research Archive
Home :: Log In :: Submit :: Alerts ::

TARA >
PEER Project >
PEER Publications >

Please use this identifier to cite or link to this item: http://hdl.handle.net/2262/65773

Title: Validation of an effervescent spray model with secondary atomization and its application to modelling of a large-scale furnace
Keywords: drop-size distribution
effervescent atomization
modelling
spray combustion
Issue Date: 10-Jun-2011
Publisher: Elsevier
Abstract: Abstract The present work consists of a validation attempt of an effervescent spray model with secondary atomization. The objective is the simulation of a 1 MW industrial-type liquid fuel burner equipped with effervescent spray nozzle. The adopted approach is based on a double experimental validation. Firstly, the evolution of radial drop size distributions of an isothermal spray is investigated. Secondly, the spray model is tested in a swirling combustion simulation by means of measured wall heat flux profile along the flame. In the first part of the paper, both experiments are described along with the measuring techniques. Drop sizes and velocities measured using a Dantec phase/Doppler particle analyser are analysed in detail for six radial positions. Local heat fluxes are measured by a reliable technique along the furnace walls in a large-scale water-cooled laboratory furnace. In the second part Euler – Lagrange approach is applied for two-phase flow spray simulations. The adopted spray model is based on the latest industrially relevant (i.e. computationally manageable) primary and secondary breakup sub-models complemented with droplet collision model and a dynamic droplet drag model. Results show discrepancies in the prediction of radial evolution of Sauter mean diameter and exaggerated bimodality in drop size distributions. A partial qualitative agreement is found in radial evolution of drop size distributions. Difficulties in predicting the formation of small drops are highlighted. Comparison of the predicted wall heat fluxes and measured heat loads in swirling flame combustion simulation shows that the absence of the smallest droplets causes a significant elongation of the flame.
URI: http://hdl.handle.net/2262/65773
ISSN: 13594311 (ISSN)
DOI: 10.1016/j.applthermaleng.2011.04.025
Rights: 2011
Affiliation: Institute of Process and Environmental Engineering, Faculty of Mechanical Engineering, Brno University of Technology - Technická 2896/2--> , 616 69 Brno--> - CZECH REPUBLIC (Broukal, Jakub)
CZECH REPUBLIC (Broukal, Jakub)
Institute of Process and Environmental Engineering, Faculty of Mechanical Engineering, Brno University of Technology - Technická 2896/2--> , 616 69 Brno--> - CZECH REPUBLIC (Hájek, Jiří)
Appears in Collections:PEER Publications

Files in This Item:

File Description SizeFormat
PEER_stage2_10.1016%2Fj.applthermaleng.2011.04.025.pdf844.46 kBAdobe PDFView/Open