The University of Dublin | Trinity College -- Ollscoil Átha Cliath | Coláiste na Tríonóide
Trinity's Access to Research Archive
Home :: Log In :: Submit :: Alerts ::

TARA >
School of Physics >
Physics >
Physics (Scholarly Publications) >

Please use this identifier to cite or link to this item: http://hdl.handle.net/2262/64033

Title: Review of ultrasound elastography quality control and training test phantoms
Author: FAGAN, ANDREW JOHN
Author's Homepage: http://people.tcd.ie/faganan
Keywords: Elastography
phantoms
Ultrasound
Issue Date: 2012
Publisher: Royal Society of Medicine Press
Citation: S. Cournane, A.J. Fagan and J.E. Browne, Review of ultrasound elastography quality control and training test phantoms, Ultrasound, 20, 2012, 16 - 23
Series/Report no.: Ultrasound;20
Abstract: While the rapid development of ultrasound elastography techniques in recent decades has sparked its prompt implementation in the clinical setting adding new diagnostic information to conventional imaging techniques, questions still remain as to its full potential and efficacy in the hospital environment. A limited number of technical studies have objectively assessed the full capabilities of the different elastography approaches, perhaps due, in part, to the scarcity of suitable tissue-mimicking materials and appropriately designed phantoms available. Few commercially-available elastography phantoms possess the necessary test target characteristics or mechanical properties observed clinically, or indeed reflect the lesion-to-background elasticity ratio encountered during clinical scanning. Thus, while some phantoms may prove useful, they may not fully challenge the capabilities of the different elastography technniques, proving limited when it comes to quality control (QC) and/or training purposes. Although a variety of elastography tissue-mimicking materials, such as agar and gelatine dispersions, co-polymer in oil and poly(vinyl) alcohol cryogel, have been developed for specific research purposes, such work has yet to produce appropriately designed phantoms to adequately challenge the variety of current commercially-available elastography applications. Accordingly, there is a clear need for the further development of elastography TMMs and phantoms to keep pace with the rapid developments in elastography technology, to ensure the performance of these new diagnostic approaches are validated, and for clinical training purposes.
Description: PUBLISHED
URI: http://hdl.handle.net/2262/64033
Appears in Collections:Physics (Scholarly Publications)

Files in This Item:

File Description SizeFormat
Cournane et al., Review of Ultrasound Elastography Quality Control and Training final.docAccepted for publication (author's copy) - Peer Reviewed337.5 kBMicrosoft WordView/Open


This item is protected by original copyright


Please note: There is a known bug in some browsers that causes an error when a user tries to view large pdf file within the browser window. If you receive the message "The file is damaged and could not be repaired", please try one of the solutions linked below based on the browser you are using.

Items in TARA are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback