Title: Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties
Author: FAGAN, ANDREW JOHN
Sponsor: Science Foundation Ireland
Author's Homepage: http://people.tcd.ie/faganan
Keywords: Bioengineering
highly viscoelastic
Issue Date: 2010
Citation: S. Cournane, L.M. Cannon, J.E. Browne, A.J. Fagan, Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties, Physics in Medicine and Biology, 55, 19, 2010, 5965-5983
Series/Report no.: Physics in Medicine and Biology
55
19
Abstract: The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner’s accuracy has not been fully established. The Young’s elastic modulus values of 5-6wt% PVA-cryogel phantoms, also containing glycerol and 0.3μm Al2O3 and 3μm Al2O3, were measured using a ‘gold standard’ mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6-16.1kPa and 1540-1570m/s, respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated the Young’s elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the singlepoint acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system’s assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.
Description: PUBLISHED
URI: http://hdl.handle.net/2262/41180
Related links: http://dx.doi.org/10.1088/0031-9155/55/19/022
Appears in Collections:Physics (Scholarly Publications)

Files in This Item:

File Description SizeFormat
Cournane 2010.pdfPublished (author's copy) - Peer Reviewed839.89 kBAdobe PDFView/Open


This item is protected by original copyright


Please note: There is a known bug in some browsers that causes an error when a user tries to view large pdf file within the browser window. If you receive the message "The file is damaged and could not be repaired", please try one of the solutions linked below based on the browser you are using.

Items in TARA are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback