The University of Dublin | Trinity College -- Ollscoil Átha Cliath | Coláiste na Tríonóide
TARA Trinity's Access to Research Archive
Home :: Log In :: Submit :: Alerts ::

TARA >
School of Physics >
Physics >
Physics (Scholarly Publications) >

Please use this identifier to cite or link to this item: http://hdl.handle.net/2262/31446

Title: Langmuir probe characterization of laser ablation plasmas
Author: LUNNEY, JAMES GERARD
Author's Homepage: http://people.tcd.ie/jlunney
Keywords: Physics
Issue Date: 2009
Publisher: Elsevier
Citation: Doggett, B., Lunney, J.G. 'Langmuir probe characterization of laser ablation plasmas' in Journal of Applied Physics, 105, (3), 2009, no. 033306
Series/Report no.: Journal of Applied Physics
105
3
Abstract: For laser ablation plumes that are significantly ionized, Langmuir probes have proved to be a useful tool for measuring the plume shape, ion energy distribution, and electron temperature. Typically in laser ablation plasmas the flow velocity is supersonic, which complicates the interpretation of the current-voltage probe characteristic. In this paper we describe some recent developments on the application of Langmuir probes for laser ablation plume diagnosis. We have investigated the behavior of the probe when it is orientated perpendicular, and parallel, to the plasma flow, and show how an analytical model developed for plasma immersion ion implantation, can quantitatively describe the variation of the ion current with probe bias for the case when the plasma flow is along the probe surface. The ion signal recorded by a probe in the parallel position is proportional to the ion density and the square root of the bias voltage. It is shown that the current varies as mi −1/2 so that by comparing the ion signals from the parallel and perpendicular positions it is possible to estimate the mass of the ions detected. We have also determined the temporal variation of electron temperature. A planar probe oriented parallel to the plasma flow, where the ion current due to the plasma flow is eliminated, gives a more reliable measurement of Te(<0.6 eV). The measured Te is consistent with the measured ion current, which is dependent on Te when the time taken for an element of plasma to traverse the probe is longer than the time taken for the matrix ion sheath extraction phase.
Description: PUBLISHED
URI: http://dx.doi.org/10.1063/1.3056131
http://hdl.handle.net/2262/31446
Appears in Collections:Physics (Scholarly Publications)

Files in This Item:

File Description SizeFormat
Langmuir probe.pdfpublished (publisher copy) peer-reviewed253.36 kBAdobe PDFView/Open


This item is protected by original copyright


Please note: There is a known bug in some browsers that causes an error when a user tries to view large pdf file within the browser window. If you receive the message "The file is damaged and could not be repaired", please try one of the solutions linked below based on the browser you are using.

Items in TARA are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback