The University of Dublin | Trinity College -- Ollscoil Átha Cliath | Coláiste na Tríonóide
Trinity's Access to Research Archive
Home :: Log In :: Submit :: Alerts ::

TARA >
School of Engineering >
Electronic & Electrical Eng >
Electronic & Electrical Eng (Scholarly Publications) >

Please use this identifier to cite or link to this item: http://hdl.handle.net/2262/17623

Title: Automatic classification of heartbeats using ECG morphology and heartbeat interval features
Author: REILLY, RICHARD
Sponsor: Enterprise Ireland
Author's Homepage: http://people.tcd.ie/reillyri
Keywords: electrocardiogram (ECG)
heartbeat classifier
Issue Date: 2004
Publisher: IEEE
Citation: de Chazal, Philip and O'Dwyer, M. and Reilly, R.B. 'Automatic classification of heartbeats using ECG morphology and heartbeat interval features' in IEEE Transactions on Biomedical Engineering, 51, (7), 2004, pp. 1196 – 1206.
Series/Report no.: 51
7
Abstract: A method for the automatic processing of the electrocardiogram (ECG) for the classification of heartbeats is presented. The method allocates manually detected heartbeats to one of the five beat classes recommended by ANSI/AAMI EC57:1998 standard, i.e., normal beat, ventricular ectopic beat (VEB), supraventricular ectopic beat (SVEB), fusion of a normal and a VEB, or unknown beat type. Data was obtained from the 44 nonpacemaker recordings of the MIT-BIH arrhythmia database. The data was split into two datasets with each dataset containing approximately 50 000 beats from 22 recordings. The first dataset was used to select a classifier configuration from candidate configurations. Twelve configurations processing feature sets derived from two ECG leads were compared. Feature sets were based on ECG morphology, heartbeat intervals, and RR-intervals. All configurations adopted a statistical classifier model utilizing supervised learning. The second dataset was used to provide an independent performance assessment of the selected configuration. This assessment resulted in a sensitivity of 75.9%, a positive predictivity of 38.5%, and a false positive rate of 4.7% for the SVEB class. For the VEB class, the sensitivity was 77.7%, the positive predictivity was 81.9%, and the false positive rate was 1.2%. These results are an improvement on previously reported results for automated heartbeat classification systems.
Description: PUBLISHED
URI: http://ieeexplore.ieee.org/iel5/10/29004/01306572.pdf?tp=&isnumber=29004&arnumber=1306572&punumber=10
http://hdl.handle.net/2262/17623
ISSN: 51851
Appears in Collections:Electronic & Electrical Eng (Scholarly Publications)
Administrative Staff Authors (Scholarly Publications)

Files in This Item:

File Description SizeFormat
automatic.pdfpublisher pdf457.53 kBAdobe PDFView/Open


This item is protected by original copyright


Please note: There is a known bug in some browsers that causes an error when a user tries to view large pdf file within the browser window. If you receive the message "The file is damaged and could not be repaired", please try one of the solutions linked below based on the browser you are using.

Items in TARA are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback