Show simple item record

dc.contributor.authorMc Mahon, Barryen
dc.contributor.authorRegan, Julieen
dc.date.accessioned2019-11-20T12:36:45Z
dc.date.available2019-11-20T12:36:45Z
dc.date.issued2013en
dc.date.submitted2013en
dc.identifier.citationRegan J, Walshe M, Rommel N, McMahon BP, A new evaluation of the upper esophageal sphincter using the functional lumen imaging probe: a preliminary report., Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus / I.S.D.E, 26, 2, 2013, 117-23en
dc.identifier.otherYen
dc.identifier.urihttps://academic.oup.com/dote/article-abstract/26/2/117/2328932?redirectedFrom=fulltext
dc.identifier.urihttp://hdl.handle.net/2262/90773
dc.descriptionPUBLISHEDen
dc.description.abstractObjective and reliable evaluation of upper esophageal sphincter (UES) opening during swallowing based on videofluoroscopy and pharyngeal manometry challenges dysphagia clinicians. The functional lumen imaging probe (FLIP) is a portable tool based on impedance planimetry originally designed to measure esophogastric junction compliance. It is hypothesized that FLIP can evaluate UES distensibility, and can provide UES diameter and pressure measurements at rest, during swallowing, and during voluntary maneuvers. Eleven healthy adult subjects consented to FLIP evaluation. The probe was inserted transorally, and the balloon was positioned across the UES. Two 20‐mL ramp distensions were completed. Changes in UES diameter and intraballoon pressure were measured during dry and 5‐mL liquid swallows, and during voluntary swallow postures and maneuvers employed in clinical practice. The protocol was completed by 10 of 11 healthy subjects. Mean intraballoon pressure increased throughout 5‐mL (5.8 mmHg; −4.5–18.6 mmHg), 10‐mL (8.7 mmHg; 2.3–28.5 mmHg), 15‐mL (17.3 mmHg; 9.5–34.8 mmHg), and 20‐mL (31.2 mmHg; 16–46.3 mmHg) balloon volumes. Mean resting UES diameter (4.9 mm) increased during dry swallows (9.2 mm) and 5‐mL liquid swallows (7.7 mm). Mean UES diameter increased during 5‐mL liquid swallows with head turn to right (8.1 mm) and left (8.3 mm), chin tuck (8.4 mm), effortful swallow (8.5 mm), Mendelsohn maneuver (8.1 mm), and supraglottic swallow (7.8 mm). FLIP was safely inserted and distended in the UES, and provided useful quantitative data regarding UES distensibility and UES diameter changes during swallowing maneuvers. Further research is being conducted to explore the role of FLIP in UES evaluation.en
dc.format.extent117-23en
dc.language.isoenen
dc.relation.ispartofseriesDiseases of the esophagus : official journal of the International Society for Diseases of the Esophagus / I.S.D.Een
dc.relation.ispartofseries26en
dc.relation.ispartofseries2en
dc.rightsYen
dc.subjectUpper esophageal sphincteren
dc.subjectDysphagiaen
dc.subjectEvaluationen
dc.subjectFunctional Lumen Imaging Probeen
dc.titleA new evaluation of the upper esophageal sphincter using the functional lumen imaging probe: a preliminary report.en
dc.typeJournal Articleen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/mcmahoben
dc.identifier.peoplefinderurlhttp://people.tcd.ie/jureganen
dc.identifier.rssinternalid100390en
dc.rights.ecaccessrightsopenAccess
dc.subject.TCDThemeNext Generation Medical Devicesen
dc.subject.TCDTagDYSPHAGIAen
dc.identifier.orcid_id0000-0002-0474-6710en


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record