Show simple item record

dc.contributor.authorMAHER, VINCENTen
dc.date.accessioned2016-01-08T14:46:23Z
dc.date.available2016-01-08T14:46:23Z
dc.date.created2014en
dc.date.issued2014en
dc.date.submitted2014en
dc.identifier.citationMac Ananey Oscar, Mellotte Greg, Maher Vincent, Comparison of semi-automated and manual measurements of carotid intima-media thickening, BioMed research international, 2014, 2014en
dc.identifier.issn2314-6133en
dc.identifier.otherYen
dc.identifier.urihttp://hdl.handle.net/2262/75556
dc.descriptionPUBLISHEDen
dc.description.abstractCarotid intima-media thickening (CIMT) is a marker of both arteriosclerotic and atherosclerotic risks. Technological advances have semiautomated CIMT image acquisition and quantification. Studies comparing manual and automated methods have yielded conflicting results possibly due to plaque inclusion in measurements. Low atherosclerotic risk subjects were recruited to minimise the effect of focal atherosclerotic lesions on CIMT variability. CIMT was assessed by high-resolution B-mode ultrasound (Philips HDX7E, Phillips, UK) images of the common carotid artery using both manual and semiautomated methods (QLAB, Phillips, UK). Intraclass correlation coefficient (ICC) and the mean differences of paired measurements (Bland-Altman method) were used to compare both methodologies. The ICC of manual ( mm) and automated (0.524 ± 0.068 mm) methods was and an absolute mean bias ± SD of  mm was observed. Interobserver and intraobserver ICC were greater for automated ( and 0.99) compared to manual ( and 0.88) methods. Although not considered to be clinically significant, manual measurements yielded higher values compared to automated measurements. Automated measurements were more reproducible and showed lower interobserver variation compared to manual measurements. These results offer important considerations for large epidemiological studies.en
dc.publisherHindawi Publishing Corporationen
dc.relation.ispartofseriesBioMed research internationalen
dc.relation.ispartofseries2014en
dc.rightsYen
dc.subjectCarotid intima-media thickening (CIMT)en
dc.titleComparison of semi-automated and manual measurements of carotid intima-media thickeningen
dc.typeJournal Articleen
dc.type.supercollectionscholarly_publicationsen
dc.type.supercollectionrefereed_publicationsen
dc.identifier.peoplefinderurlhttp://people.tcd.ie/vmmaheren
dc.identifier.rssinternalid108555en
dc.rights.ecaccessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record